Titration:
Never Lose a Practical Mark Again
You can already do the calculation. This is about every other mark.
Written by SystemOne's state-ranked chemistry tutors. It's a taste of how we teach in class: the why behind every step.
7 rules that save practical marks
If you only read one page, read this one. The rest of the guide explains the why behind each.
Start with a number you can trust
A titration finds an unknown concentration by reacting it with a solution whose concentration you know exactly: a standard solution. If that number is wrong, every result after it is wrong too.
A primary standard is pure and stable enough that you can weigh it and know exactly how many moles you have.
| Property | Why it matters |
|---|---|
| High purity, known formula | Mass converts to moles exactly (n = m/M) |
| Stable in air | Doesn't absorb water or CO₂ while you weigh it, so the mass stays true |
| High molar mass | More grams for the same moles, so the balance's small error is a smaller percentage |
| Soluble in water | It all dissolves in the volumetric flask |
Examples: anhydrous sodium carbonate (Na₂CO₃), potassium hydrogen phthalate (KHP), hydrated oxalic acid (H₂C₂O₄·2H₂O).
NaOH is hygroscopic: it absorbs water from the air, so part of the mass you weigh is water and you have fewer moles than you calculated. It also reacts with carbon dioxide in the air: 2NaOH(s) + CO₂(g) → Na₂CO₃(s) + H₂O(l). Its composition keeps changing, so its mass can't tell you its moles.
The fix: make NaOH up to roughly the right concentration, then standardise it by titrating it against a primary standard.
Weigh the solid accurately on an electronic balance and record the mass.
Dissolve it in a beaker with a small amount of distilled water.
Pour the solution into the volumetric flask through a funnel.
Rinse the beaker, stirring rod and funnel with distilled water into the flask. Why: Every bit of solute must end up in the flask, or you lose moles.
Add distilled water to just below the line, then dropwise until the bottom of the meniscus sits on the line at eye level. Why: The flask is calibrated for one exact volume, e.g. 250.00 mL. A beaker or measuring cylinder is nowhere near that accurate.
Stopper and invert several times. Why: Otherwise the concentration differs from top to bottom.
Rinse it with what it's about to hold
Ask one question: does this glass measure a volume of a solution, or just hold moles? Measuring glass is rinsed with its own solution so nothing dilutes it. The flask only holds moles, and extra water doesn't change moles.
| Glassware | Final rinse with | Why |
|---|---|---|
| Burette | The solution it will hold (the titrant) | Leftover water dilutes the titrant, so more volume is needed to deliver the same moles. Wrong concentration, wrong titre. |
| Pipette | The solution it will measure | Leftover water dilutes the aliquot, so your 25.00 mL holds fewer moles than you think. |
| Conical flask | Distilled water only | It only has to contain the moles the pipette delivers. Water adds none. Rinsing it with the solution leaves extra moles behind, and the titre comes out too large. |
Burette and pipette: water would dilute, so rinse with the solution. Conical flask: the solution would add extra moles, so rinse with water.
Clamp it vertically and fill above the zero mark using a funnel.
Remove the funnel. Drips from it top up the burette mid-titration, so the reading shows less than was delivered.
Run some liquid out to fill the tip and push out any air bubble. A bubble that escapes mid-titration gets counted as volume delivered.
Read the bottom of the meniscus at eye level. Avoids parallax error. The first reading doesn't need to be 0.00 mL; just record it.
Use a pipette filler, never your mouth.
Draw the solution above the line, then let it fall until the bottom of the meniscus sits on the line at eye level.
Let it drain into the flask, then touch the tip against the inside wall. This drains the outside drop in a consistent way.
Don't blow out the last drop. The pipette is calibrated to deliver exactly 25.00 mL with that drop left inside.
Pages 2 to 4 are technique you can fix tonight. From here it's the theory behind the "explain why" questions. In class we work through every Module 6 curve and practical, with weekly quizzes marked against the HSC rubric.
Read the indicator off the pH curve
An indicator is a weak acid (or base) whose two forms are different colours, so it changes colour over a pH range. The rule: the indicator's range must sit inside the steep part of the curve, where the equivalence point is.
| Indicator | Colour change | pH range | Use for |
|---|---|---|---|
| Methyl orange | red → yellow | 3.1–4.4 | Strong acid + weak base |
| Bromothymol blue | yellow → blue | 6.0–7.6 | Strong acid + strong base |
| Phenolphthalein | colourless → pink | 8.3–10.0 | Weak acid + strong base |
Equivalence at pH 7. The jump is so tall that all three indicators work.
Equivalence at about pH 8.7, because CH₃COO⁻ + H₂O ⇌ CH₃COOH + OH⁻. Use phenolphthalein.
Equivalence at about pH 5.3, because NH₄⁺ + H₂O ⇌ NH₃ + H₃O⁺. Use methyl orange.
Too much indicator is an error. It's a weak acid or base itself, so it reacts with some titrant and blurs the colour change. Use 2–3 drops.
Weak acid + weak base curves have no steep section, so no indicator gives a sharp endpoint.
Endpoint, titres and the maths
Equivalence point: the acid and base have reacted in exactly the mole ratio from the balanced equation. You can't see it.
Endpoint: the indicator changes colour. You can see it.
A good indicator makes the endpoint land on (or very near) the equivalence point.
Put a white tile under the flask so the first colour change is obvious.
Do a fast rough titre to find roughly where the endpoint is.
Then run quickly to 1–2 mL before that value and go dropwise while swirling.
Wash stray droplets on the flask walls (and any drop hanging from the burette tip) into the solution with distilled water. They're titrant that hasn't reacted yet; water adds no moles.
Stop at the first permanent colour change.
Repeat until you have three concordant titres (within 0.10 mL).
1.325 g of anhydrous Na₂CO₃ is dissolved and made up to 250.0 mL in a volumetric flask. 25.00 mL aliquots are titrated with HCl using methyl orange. Titres: rough 23.10 mL, then 22.45, 22.50 and 22.40 mL. Calculate the concentration of the HCl.
Balanced equation. Na₂CO₃(aq) + 2HCl(aq) → 2NaCl(aq) + H₂O(l) + CO₂(g)
Concentration of the standard. n(Na₂CO₃) = m/M = 1.325 / 105.99 = 0.01250 mol, so c = 0.01250 / 0.2500 = 0.05000 mol L⁻¹
Average titre (concordant only). 22.45, 22.50 and 22.40 are within 0.10 mL. The rough 23.10 is left out. Average = 22.45 mL
Moles in the aliquot. n(Na₂CO₃) = c × V = 0.05000 × 0.02500 = 1.250 × 10⁻³ mol
Use the mole ratio (1 : 2). n(HCl) = 2 × 1.250 × 10⁻³ = 2.500 × 10⁻³ mol
Concentration of HCl. c = n/V = 2.500 × 10⁻³ / 0.02245 = 0.1114 mol L⁻¹ (4 significant figures, matching the data)
Convert mL to L before multiplying (25.00 mL = 0.02500 L), and keep extra figures in your working. Round only the final answer.
Every mistake, and exactly what it does
Setup: the known solution (titrant) is in the burette, the unknown is pipetted into the conical flask, and you're calculating the unknown's concentration. "Too high" means your answer comes out bigger than the true value.
| Mistake | What it does | Your answer |
|---|---|---|
| Burette rinsed with water only | Titrant is diluted, so more volume is needed to deliver the same moles. Titre too large. | Too high |
| Pipette rinsed with water only | Aliquot is diluted, so fewer moles of unknown go into the flask. Titre too small. | Too low |
| Conical flask rinsed with the unknown | Extra moles of unknown are left in the flask. Titre too large. | Too high |
| Conical flask still wet with distilled water | Moles in the flask are unchanged. Only the total volume changes, and that is not in the calculation. | No effect |
| Air bubble in the burette tip escapes | The level drops by the bubble's volume too, so the recorded titre is bigger than what reached the flask. | Too high |
| Funnel left in the burette | Drips refill the burette during the titration, so the reading shows less than was delivered. Titre too small. | Too low |
| Last drop blown out of the pipette | More than 25.00 mL, so more moles of unknown, go into the flask. Titre too large. | Too high |
| Not going dropwise near the endpoint | You overshoot the endpoint with extra titrant. Titre too large. | Too high |
| Droplets on the flask wall not washed down | Titrant counted in the reading never reacted, so more has to be added to reach the endpoint. Titre too large. | Too high |
| Methyl orange for CH₃COOH + NaOH | It changes at pH 3.1–4.4, long before the equivalence point at about pH 8.7. Titre too small. | Too low |
| Too much indicator | The indicator reacts with some titrant and the colour change is less sharp. | Inaccurate |
| Rough titre included in the average | The rough run usually overshoots, so it drags the average up. | Too high |
| NaOH weighed as if it were a primary standard (NaOH in the burette) | Real [NaOH] is lower than you assumed, so you multiply a larger titre by a concentration that is too high. | Too high |
Trace every mistake through the same chain: moles in the flask → titre → calculated concentration. If the titre goes up, so does your answer.
Try them, then check the full-mark answer
Explain why sodium hydroxide is not used as a primary standard, and outline how the concentration of a sodium hydroxide solution can be found accurately.
3 marksA student titrates ethanoic acid with sodium hydroxide using methyl orange. Assess the student's choice of indicator.
3 marks25.00 mL of vinegar was diluted to 250.0 mL. 25.00 mL aliquots of the diluted solution were titrated with 0.1050 mol L⁻¹ NaOH. Concordant titres were 19.80, 19.85 and 19.90 mL. Calculate the concentration of ethanoic acid in the original vinegar.
4 marksn(NaOH) = 0.1050 × 0.01985 = 2.084 × 10⁻³ mol = n(CH₃COOH) (1 : 1 ratio).
c(diluted) = 2.084 × 10⁻³ / 0.02500 = 0.08337 mol L⁻¹.
Diluted 10 times, so c(original) = 0.8337 mol L⁻¹.
A student dissolved 2.00 g of NaOH pellets from a container left open for a week, made the solution up to 500.0 mL, and assumed its concentration was 0.100 mol L⁻¹. They used it in a burette to find the concentration of HCl pipetted into a flask, and got three concordant titres. (a) Explain why concordant titres do not show that the result is accurate. (2) (b) Explain the effect on the calculated HCl concentration, and propose an improvement. (3)
5 marks · hardThat was one practical.
Imagine the whole course.
Learn from state-ranked tutors who know what markers look for.
8 students max, so every question gets answered.
Weekly quizzes marked against the HSC rubric.
Support, not added stress.
The full Module 6 booklets · every pH curve and calculation type worked through · weekly quizzes marked to the HSC rubric · personalised feedback on your "explain why" answers
Stop losing the marks you already know.
Sign up for a class s1education.com.au/holiday-classes · 8 students max